Leak detection in Harwich

Leak detection Harwich, the old town and Dovercourt

Harwich sits right at the end of the A120. Charlie brings the kit to trace a leak through a Georgian floor or a 1960s slab.

No find, no fee

Old town and Dovercourt

Report written for your claim

Get a quote

Tell us what you have noticed and where. We ring you back to talk it through. No find, no fee.

No find, no fee

24/7 enquiries

Non-invasive methods

Reports for insurance claims

Harwich leak detection means two very different towns. The old town on the point is a grid of Georgian and earlier houses, many now flats, with pipework threaded through old brick and under floors that have been down for centuries. Dovercourt and Parkeston behind it are terraces, 1930s semis and post war estates on solid floors.

In the old town the problem is shared pipework and old joints, and the first question is whose pipe it is. In Dovercourt the problem is heating pipe in screed, which shows only as a boiler that will not hold pressure. Essex and Suffolk Water supply Harwich.

Water meter chamber at the boundary of a Essex house Leak detection engineer using a thermal imaging camera inside a Essex home

A Harwich visit in three parts

1

Settle whose pipe it is

In a converted old town house Charlie isolates the communal supply, each flat's feed and each heating system in turn. The one that loses water is at fault, and the report names it.

2

Test the house systems

In a single house the mains is shut at the stop tap and the meter checked, then the heating is pressurised and watched. The failing system is the only one traced.

3

Pinpoint and record

The thermal camera finds the run, the microphone finds the sound and tracer gas confirms the spot. Charlie marks it, photographs it and writes it up for the insurer if needed.

The tools that come to Harwich

Thermal imaging

Thick old walls and floors in the old town hold temperature evenly, so a warm pipe or a cold wet patch stands out clearly. In Dovercourt it maps the heating loops under the screed.

Acoustic listening

Supply pipes under the narrow pavements and yards of the old town, and under the longer gardens of Dovercourt, are followed with a ground microphone until the hiss peaks over the break.

Tracer gas

A heating circuit that is losing pressure silently is drained and charged with a hydrogen mix. The gas finds its way up through boards, flags or screed at the split, and the detector marks it.

Leaks we have traced in Harwich and Dovercourt

A Georgian house in the old town, now split into flats, had water coming through a first floor ceiling. We isolated the communal supply, each flat's feed and each heating system in turn, and the loss was on the hot water pipe of the flat above. The report said so, which settled who claimed. In Dovercourt a post war house had a boiler losing pressure, and the thermal camera traced the heating pipe in the screed to a joint under the kitchen, confirmed with tracer gas. A 1930s semi in Parkeston had a meter that kept turning with the house shut off. Listening along the supply pipe put the break under the front path.

Nearby places we cover

Manningtree is 15 minutes back along the Stour, Frinton On Sea is a short run down the coast, and Colchester and Wivenhoe are on the same run. Harwich leak detection is the far end of the leak detection Essex run and shares the diary with all of them.

Insurance claims for Harwich properties

Trace and access cover pays for locating the leak and for opening up to reach it, and in a converted old town building that can be the expensive part. Our report records the tests, whose pipe failed, the thermal images and the marked position.

Questions people ask

Yes. We cover Tendring regularly. Harwich is booked onto the same run as Clacton and Manningtree, so 24 to 48 hours is normal.

By testing. Our engineer isolates your supply and your heating and watches for any loss. If both are tight, your pipes are not the cause, and the report says so. He then checks the communal pipework if access is given.

Pressure test the heating to confirm the loss, run the thermal camera over the floor with the heating on to see the spreading patch, then drain the circuit and use tracer gas to mark the exact point.

Not for finding the leak. Lead is traced like any other pipe. The report will say it is lead, because once lead starts to fail it tends to keep failing, and many owners replace the run.

No. The visit is no find, no fee, and that includes the drive. If every test is clean we tell you what else could be behind the damp.

Book leak detection in Harwich

Call us on 07897 020 680 and say if you are in the old town, Dovercourt or Parkeston.

Landline 01440 840 772. Email hello@completeleakdetection.co.uk.